January 2025
EXCLUSIVE!

Corepharma Covid-19/RSV/Influenza A&B Antigen Test Kit 1 Test

Product ID: 2730118

$7.99

Select your location to check stock

Enter your location to check stock levels in-store and online.

The COVID-19/RSV/Influenza A&B Antigen Test Kit is a lateral flow immunoassay for the qualitative detection
of SARS-CoV-2, respiratory syncytial, influenza A and influenza B viral nucleoprotein antigens in nasal swabs
from subjects. The symptoms of respiratory viral infection due to SARS-CoV-2, respiratory syncytial, influenza can be similar. The test is intended as an aid in diagnosis of symptomatic individual meeting respiratory
infection for SARS-CoV-2 (within the first 7 days of the onset of symptoms) and influenza A/B or Respiratory
syncytial virus (RSV) (within the first 4 days of the onset of symptoms). This kit is intended for layperson's home
use in a non-laboratory environment. Test results of this kit are for clinical reference only. It is recommended
that a comprehensive analysis of the disease be conducted based on clinical manifestations of patients and other laboratory tests.                                                                                                                  Test Kit includes:
Test cassette - 1
Extraction Buffer tube - 1
Disposable Swab - 1
Biohazard Specimen Bag - 1
Instruction for use - 1

1. For in vitro diagnostic use only.
2. Do not use after the expiration date.
3. Perform the test at room temperature 15 to 30°C.
4. The test cassette should remain in the sealed pouch until use.
5. Please read all information in this leaflet before performing the test.
6. Components from difference lots must not be mixed or used together.
7. Positive result cannot necessarily determine whether a person is infectious.
Storage:                                                                                                                                                                                                      Store the test kit in the original packaging at 2°C - 30°C. Do not freeze. Test kit contents remain stable until the expiration date printed on the outer packaging.  After opening the pouch, the test should be used within one hour. Prolonged contact with hot and humid environment will cause the product to deteriorate.

The COVID-19/RSV/Influenza A&B Antigen Test Kit is a lateral flow immunoassay for the qualitative detection
of SARS-CoV-2, respiratory syncytial, influenza A and influenza B viral nucleoprotein antigens in nasal swabs
from subjects. The symptoms of respiratory viral infection due to SARS-CoV-2, respiratory syncytial, influenza can be similar. The test is intended as an aid in diagnosis of symptomatic individual meeting respiratory
infection for SARS-CoV-2 (within the first 7 days of the onset of symptoms) and influenza A/B or Respiratory
syncytial virus (RSV) (within the first 4 days of the onset of symptoms). This kit is intended for layperson's home
use in a non-laboratory environment. Test results of this kit are for clinical reference only. It is recommended
that a comprehensive analysis of the disease be conducted based on clinical manifestations of patients and other laboratory tests.   

For self-testing. Please read the instructions carefully before performing the test. The test can only be performed one time. Testing by adult only.
Results will appear 15 minutes after the test is completed. OR use full instructions here:  Wash your hands thoroughly, then prepare the extraction tube by tearing off the aluminum foil and placing the tube in the stand. Open the swab package without touching the swab tip. Tilt your head slightly back, insert the swab 1.5–2.5 cm into one nostril, and gently rotate it five times against the nasal wall. Repeat in the other nostril. Place the swab in the extraction tube, rotate it five times against the tube walls, and let it sit for 1 minute. Remove the swab while squeezing the tube to extract the liquid, then secure the nozzle cap. Open the test device and add three drops to the specimen wells. Read the result at 15 minutes. DO NOT interpret the result after 20 minutes. Dispose of used components in a sealed biohazard bag, discard it in general waste, and wash your hands again.